- Locations: Kurla - Mumbai Abu Dhabi Dubai Doha Jeddah Riyadh Salalah Kuwait City Ras al Khaimah Dammam Qudaibiya - Manama
- Duration: 3 Days
Course details
Topic Covers
Module 1: Introduction and Background.
This module contains Components of Power System, System Running Condition, Aim of Protection, Fault Statistics, Protection Zones, Requirements of a Good Relay, Protection System Components, Time of Action, Calculation of Fault Currents, Modelling of Power System During Faults, and Power System Grounding. This module contains more than 6 examples and exercises.
Module 2: Protection System Components.
This module contains Protection Transformers, Current Transformers, Current Transformer Errors, Methods of Assessment of Current Transformer Errors, Voltage Transformers, Capacitor Voltage Transformers, Fuses, High Rupturing Capacity (HRC) Fuse, Fusing Factor, Circuit Breakers, AC Circuit Breakers, Air Circuit Breakers, SF6 Circuit Breakers, Oil Circuit Breakers, Vacuum Circuit Breakers, DC Circuit Breaking, DC Commutation Methods, DC Circuit Breakers, and Future Trend of Circuit Breakers. This module contains more than 10 examples and exercises.
Module 3: Protection Relays.
This module contains Classification of Protection Relays, Electromagnetic Relays, Applications of Relays, Single Quantity Relays, Two Input Relays, Differential Relays, Ratio or Percentage Differential Relays, Percentage Differential Relay, and Impedance or Distance Relays.
Module 4: Protection Schemes.
This module contains Over Current Protection, Protection Grading, Directional Over Current Protection, Over Current Earth Fault Protection, Differential Protection, Distance Protection, Zones of Protection and Time Grading, Types of Distance Relays, and Fault Resistance. Module 5: Protection of Transmission Lines.
This module contains Over Current Protection, Overcurrent Earth Fault Protection, Distance Protection, and Pilot Protection.
Module 6: Protection of Plants.
This module contains Generator Protection including Differential Protection, Overcurrent and Earth Fault Protection, Negative Phase Sequence Protection, Turn To Turn Stator Protection, Loss of Excitation Protection, Reverse Power Protection, Over Frequency and Under Frequency Protection, Over Voltage Protection, Thermal Protection, and Over Speed Protection. Transformer Protection including Over Current Protection, Differential Protection, Buchholz Relay, Coolant Level Protection, and Over Temperature Protection. Motor Protection including Mechanical Overloading Protection, Short Circuit Protection, Earth Faults Protection, Stalling Protection, Single Phasing Protection, Winding Temperature Protection, and Under Voltage Protection. Cable Protection. This module contains more than 6 examples and exercises.
Updated on 18 September, 2019Job roles this course is suitable for:
All participants will be provided with a “Successfully completed course” certificate for those participants who satisfy the following conditions 100% attendance in the class Submit all the course work and assignments Successful completion of the End of course AssessmentCourse Location
About Prolific Systems And Technologies Pvt. Ltd.
Prolific Systems & Technologies Pvt. Ltd. Started 1997 in India by technocrat promoters with engineering background and industrial work experience. Prolific provides turnkey automation solutions and Technical Training services to over 200 manufacturing firms across the globe. Prolific employs over 300 technical professionals on its payroll. Prolific is an established industrial training brand in “India and Middle East”.
- Engineering: Power System Analysis– Part 2 Course CentralINR 1,932
INR 10,873Duration: Upto 2 Hours - Cable and Wire Management Awareness Certification Courses Distance Learning Ltd.INR 4,229
INR 8,457Duration: Upto 3 Hours